Rig Loses Module Power and Emergency Lights Randomly

Anderson Fleet Service · Kinsman, OH

Rusted-out battery ground bolt removed from the frame of a Braun ambulance

Had a rig that would randomly lose module power and emergency lights. No pattern, no warning. Just gone, then back.

That’s not something you want happening on a call.

Step 1: Check the usual suspects

Started with the basics:

  • Battery cables
  • All the connections in the cabinet
  • Voltage to the trigger wire on the main relay for the module

All OK.

When the power side checks out, it’s time to look at the other half of the circuit. We’re in the rust belt. Grounds were next.

Step 2: The back ground strap

On the very back of this ambulance there’s a frame-to-box ground strap. It was attached, but it was corroded.

Took it apart, wire brushed both surfaces, put it back together and covered it in anti-corrosion spray. I use CorrosionX HD.

Nothing about that one made me 100% sure I’d found it. So I kept going.

Step 3: The middle ground strap

Next one was at the middle of the module body, running up to the cross member. Corroded too.

The cross member side was fine. The module side wasn’t. The module’s aluminum, and it seems to corrode way faster.

Wire brushed it, cleaned up both surfaces, and coated it.

Step 4: The battery grounds

Last, I wanted to check the grounds from the battery cables themselves. This was a Braun with the battery compartment on the lower passenger side. Behind there, there’s typically a direct ground to the frame.

Looking up between the module and the frame, there’s just enough room to get your hands in. I could see two heavy-gauge ground cables going to the frame.

They honestly didn’t look that bad. But I figured I’d better take them apart and check.

Put my wrench on the bolt, and it fell apart. Completely rusted out. The only thing holding it in there was friction.

Both bolts.

Cleaned up the cables and the frame, put in new stainless bolts, and covered everything in anti-corrosion spray. Now I was confident I’d found it.

The customer never reported the problem again.

Takeaways from the field

  • Power checks out? Check the ground side. Half the circuit is the return path.
  • In the rust belt, check every ground, not just the first ugly one. This truck had three bad spots.
  • Aluminum bodies seem to corrode faster at the ground. Pay extra attention to the module side.
  • Don’t trust a ground because it looks OK. Take it apart. That bolt looked fine until the wrench touched it.
  • Clean both surfaces, use stainless hardware, and coat it. Otherwise you’ll be back doing it again.

Final word

Random power loss feels like it could be anything, but bad grounds are one of the most common causes, especially up here. If your rig is dropping power or lights for no reason, give us a call.